1
The Firetech FT-CFP2002-2 series conventional fire alarm panel is
designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to
32 zones easily
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input .
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm
immediately.
12 It has battery low protection function, when battery voltage
lower than 21VDC,
battery will be cut off automatically until
the mains power is on.
13 It has an optional GSM module for fire alarm by SMS .
14 It is economic, user-friendly and easy maintenance.
Parameters:
ITEM 2 Zone panel
Model No. FT-CFP2002-2
Power specification
Mains supply voltage 110VAC or
240VAC
Internal power supply
27.2VDC
Total output current limited 500mA @
240VAC
Main supply monitor for fault
Yes
Battery protection for low voltage
Yes
Batteries (default configuration)
12V2AH*2
Detector circuit specification
Number of circuit 2
Line fault monitor for open circuit
Yes
Line fault monitor for short circuit
Yes
Line fault monitor for detector removal Yes, if End
of Line Monitor Unit fitted in place of End of Line
Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour
code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky
type (required if End of Line Monitor Unit fitted to give Detector
Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5
watt
Maximum number of smoke/heat detectors per zone 20
(based on a total detector current of 2mA, each detector consuming
100μA).Note: if End of Line Monitor Unit is fitted,
for correct operation maxmum voltage drop must not exceed 12
volts.
Maximum number of manual call points per zone No
limit
Sounder circuit specification
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W
(colour code-blue,grey,red,gold)
Line fault monitor for open circuit
Yes
Line fault monitor for short circuit
Yes
Outputs fused AT
400mA
Maximum number of bells @ 20mA of each sounder output
20
Fuses
Battery fuse 1.5A F
20mm
Sounder outputs 500mA F
20mm
Fire and fault output
Output type NC and NO
relay
Maximum current
100mA
Connection block
Largest acceptable conductor size
2.5mm2
Smallest acceptable conductor size
0.75mm2
Size and weight
Dimensions(mm)
395*502*125mm
Weight (without batteries)
7kg
Fire_Alarm
Firetech 2-Zones Conventional Fire Alarm control Panel(FT-CFP2002-2)