Firetech 4-Zones Conventional Fire Alarm control Panel(FT-CFP2002-4)


Firetech 4-Zones Conventional Fire Alarm control Panel(FT-CFP2002-4)

218,663.96 304,630.94

1 The Firetech FT-CFP2002-4 series conventional fire alarm panel is
designed based on EN54 part 2&4 standard.
 2 It is modularized design, the panel can expend from 1 zone to
32 zones easily
 3 It has 2 level control mode by a lock
 4 It has 24VDC and 5VDC power supply output.
 5 It has FIRE and FAULT signal output.
 6 It has 2 general sounders output.
 7 Each zone has 1 circuit detectors input .
 8 Each zone can be disable by a button.
 9 It has RESET button to reset the panel.
 10 It has SILENCE button to stop BUZZER and SOUNDERS.
 11 It has EVACUATE button to start a manual fire alarm
immediately.
 12 It has battery low protection function, when battery voltage
lower than 21VDC,
     battery will be cut off automatically until
the mains power is on.
 13 It has an optional GSM module for fire alarm by SMS .
 14 It is economic, user-friendly and easy maintenance.
Parameters:
ITEM    4 Zone panel
Model No.    FT-CFP2002-4   
   
Power specification   
        
Mains supply voltage    110VAC or
240VAC       
Internal power supply    27.2VDC   
   
Total output current limited    500mA @
240VAC       
Main supply monitor for fault    Yes   
   
Battery protection for low voltage   
Yes       
Batteries (default configuration)   
12V2AH*2       
Detector circuit specification   
        
Number of circuit    4   
   
Line fault monitor for open circuit   
Yes       
Line fault monitor for short circuit   
Yes       
Line fault monitor for detector removal    Yes, if End
of Line Monitor Unit fitted in place of End of Line
Resistor       
End of Line device    6.8k Ω,5% tolerance, 0.25W (colour
code-blue,grey,red,gold)       
Detector continuity diodes    Silicon 1N4001 or Schottky
type (required if End of Line Monitor Unit fitted to give Detector
Removal Fault)       
Call point resistor value    470 to 680 Ω, 0.225 or 0.5
watt       
Maximum number of smoke/heat detectors per zone    20
(based on a total detector current of 2mA, each detector consuming
100μA).Note: if End of Line Monitor Unit is fitted,
for correct operation maxmum voltage drop must not exceed 12
volts.       
Maximum number of manual call points per zone    No
limit       
Sounder circuit specification   
        
Number of general circuits    4   
   
End of line resistor value    6.8k Ω,5% tolerance, 0.25W
(colour code-blue,grey,red,gold)       
Line fault monitor for open circuit   
Yes       
Line fault monitor for short circuit   
Yes       
Outputs fused AT    400mA   
   
Maximum number of bells @ 20mA of each sounder output   
20       
Fuses   
        
Battery fuse    1.5A F 20mm   
   
Sounder outputs    500mA F 20mm   
   
Fire and fault output   
        
Output type    NC and NO relay   
   
Maximum current    100mA   
   
Connection block   
        
Largest acceptable conductor size   
2.5mm2       
Smallest acceptable conductor size   
0.75mm2       
Size and weight   
 
        
Dimensions(mm)    395*502*125mm   
   
Weight (without batteries)    7kg   
   
Weight (with batteries)    9.6kg   
   